Fiber optic temperature sensor, Intelligent monitoring system, Distributed fiber optic manufacturer in China
Substation temperature monitoring device
There are many types of substations, including different kV substations, 110kV substations, substation design, box type substations, 35kV substations, intelligent substations, substation construction, 220kV substations, intelligent substations, substation engineering, high-voltage substations, etc. The temperature of substation joints is an important parameter, and substations are widely used power equipment in the construction and renovation of power system urban networks. The substation integrates and installs various electrical equipment inside the substation. Due to the concentration of various electrical equipment in a relatively enclosed environment, when the substation is in use and in a powered state for a long time, the electrical equipment will generate a large amount of heat during operation. Due to the high temperature requirements of substations, if these heat cannot be dissipated in a timely manner, it will affect the overall normal operation of the substation and easily cause damage to the electrical equipment inside the substation. For example, the electrical equipment installed in the low-voltage room of a substation has a large heat dissipation capacity. When the internal temperature of the low-voltage room of the substation is too high, it can lead to the burning or short circuit of the internal electrical equipment. Therefore, real-time online monitoring of the temperature of various equipment in the substation is important.
The temperature measurement requirements for substation equipment mainly include transformers, high-voltage circuit breakers, isolating switches, busbars, lightning arresters, capacitors, reactors, etc.
The main business of substation fiber optic temperature measurement enterprises is substation fiber optic temperature measurement. The performance of the substation fiber optic temperature measurement monitoring host is superior, the technical strength is internationally leading, and the price is reasonable.
Fiber optic temperature measurement system for substation main transformer
The main transformer is generally an oil immersed transformer, which can use a fluorescent fiber optic temperature measurement system,
According to the IEEE/ANSI or IEC Transformer Operating Load Guidelines, the upper load limit of a power transformer is set based on the winding temperature and/or top oil temperature of the transformer during normal or emergency operation. During each operating cycle of the transformer, its upper load limit can also serve as a basis for determining the remaining insulation life of the transformer. Therefore, users need to understand the actual hot spot temperature of the transformer during operation and optimize the load, maximize the asset value of the equipment, and minimize the risk of equipment overheating, sudden reduction in insulation life, and/or failure.
The independently developed transformer winding fiber optic temperature measurement device is used to monitor the critical operating temperature of power equipment. The monitored temperature data can be used to control the equipment cooling system and establish load levels. The transformer winding fiber optic temperature measurement device is easy to connect with the user’s local computer network or system, and provides temperature data to the dispatch center.
Functional purposes
(1) Real time winding hot spot temperature monitoring – can detect the winding hot spot temperature specified by the equipment manufacturer
a) Verification of Power Equipment Design Performance – Temperature Rise Test
b) Benchmark for implementing transformer performance monitoring
c) Research on Other Applications of Power Systems
(2) Real time information monitoring of transformer operation status
a) Dynamic load management and maintenance;
b) Transformer life assessment;
c) Early diagnosis of transformer latent faults – design or cooling faults;
(3) Accurate control of transformer cooling/alarm/protection system
a) Control the cooling system based on the actual temperature of the hotspot;
b) Optimize the operational performance of transformers;
System characteristics
Temperature data storage
Can choose 4, 6, or 8 detection channels
Each channel and relay setting has LED display
Equipped with system status indication and fault output relay
Solid state LED light source, no common light source aging issues
3000V overvoltage protection (IEEE C37.90.1-1989)
Circular plug-in terminal blocks facilitate external electrical wiring and signal remote transmission
New reinforced optical fiber with PTFE Teflon protective layer
Fiber optic probes are not affected by electrical and electromagnetic interference
·The system has no drift and does not require calibration
·No light source attenuation, instrument and transformer have the same lifespan
·Modbus and DNP3 communication protocols can be selected
The value of real-time monitoring of hot spot temperature in power equipment windings
-Real time winding hot spot temperature detection – can detect the winding hot spot temperature specified by the equipment manufacturer
Verification of Power Equipment Design Performance – Temperature Rise Test
Benchmark for implementing transformer performance monitoring
-Real time information on the operation status of transformers
Facilitating the implementation of equipment asset management (dynamic load management/maintenance)
Transformer life assessment (transformer service life=winding insulation=winding insulation temperature)
Early diagnosis of transformer latent faults – design or cooling faults
-Accurate control of transformer cooling/alarm/protection system
Implement cooling system control based on actual temperature of hotspots
-Optimizing the operational efficiency of transformers
-No calibration required after installation – the fluorescent temperature sensor has the same lifespan as the main device