Why do reactors need to use fluorescent fiber optic temperature measurement systems
When the reactor sends abnormal or faulty signals, the faulty area of the reactor heats up and the temperature rises. By monitoring the temperature, the operating status of the reactor can be determined, thereby achieving the goal of protecting the reactor. General temperature measurement devices cannot measure the internal temperature of reactors. To solve this problem, FJINNO’s fluorescent fiber optic temperature measurement system can solve it through its anti-interference and high-temperature and high-pressure resistance characteristics.
Introduction to Fiber Optic Temperature Measurement System for Reactors
The IF-DK series reactor optical fiber temperature measurement adopts a fluorescent optical fiber temperature measurement device. The sensing probe of this device is made of non-metallic material and quartz optical fiber, which has complete electrical insulation and is not affected by high voltage and strong electromagnetic fields. It is resistant to chemical corrosion and pollution, and has fast response speed, simple installation, and high temperature resistance. The backend software is used for real-time online monitoring. Систем нь гурван хэсгээс бүрдэнэ: a fluorescent fiber optic temperature controller, флюресцент шилэн кабелийн датчик, болон шилэн кабелийн холбооны программ хангамж.
basic function (Conventional D-type) |
1. Three winding temperature measurement; Automatic/manual start/stop of cooling fan; Temperature display value compensation function for each channel 2. Хар хайрцагны функцээр хангана, which can record the temperature data of the last power outage and the highest historical temperature; 3. Digital tube display; 4. Трансформаторын хаалганы кабинетийг нээх цэгийн дохиоллын функцээр хангана; 5. Хангах 1 set of over temperature alarm contacts (1 normally open, 1 normally closed); 6. Хангах 1 set of over temperature trip contacts (1 normally open, 1 normally closed); 7. Хангах 1 set of fan remote transmission contacts (1 normally open, 1 normally closed); 8. Хангах 1 set of temperature controller fault alarm contacts (1 normally open, 1 normally closed); |
Customized features (Customizable for special needs) |
1. Хангах 1 iron core temperature measurement and 2 iron core over temperature alarm contacts (1 normally open, 1 normally closed) (Би ажилладаг); 2. RS485 холбооны функцээр хангана, communication with time markers, capable of receiving time synchronization, MODBUS-RTU protocol (F функц); 3. Сэнсний алдаа оношлох функц, сэнсний эвдрэлийн дохиоллын контактыг хангах (L функц); 4. Хангах 4 бие даасан 4-20мА аналог гүйдлийн гаралтын функцууд (E функц); 5. Provide temperature measurement and control for the entire computer room environment; (G function) 6. Ороомгийн температурын өсөлтийн хурд болон төмрийн үндсэн температурын өсөлтийн хурдны дохиоллын функц; 7. Харилцааны протокол нь Profibus гэх мэт аргуудыг хэрэглэж болно, IEC60870-5-103, Ethernet холболт, гэх мэт; |
On site case study of fluorescence fiber optic temperature measurement device
![]() |
![]() |