ຜູ້ຜະລິດຂອງ ເຊັນເຊີອຸນຫະພູມ Fiber Optic, ລະບົບຕິດຕາມອຸນຫະພູມ, ມືອາຊີບ OEM/ODM ໂຮງງານ, ຂາຍສົ່ງ, Supplier.customized.

ອີເມລ: fjinnonet@gmail.com |

ບລັອກ

‌Multi-Channel Fluorescent Fiber Optic Sensors for HV Substations | 10kV Isolation & EMI-Proof

Fluorescent Fiber Optic Monitoring: Key Technical Advantages

Q: Why choose fluorescent fiber sensors for high-voltage equipment?

  • ±0.5°C accuracy on live 35kV switchgear contacts (IEC 62271-1 certified)
  • 64-point real-time monitoring with 15kV galvanic isolation
  • Direct winding embedding in 500MVA transformers (25kV/mm dielectric)
  • EMI immunity under 150kV/μs transients
  • Proven 99.97% uptime in 220kV substations

40% maintenance cost reduction verified in operational case studies

Fluorescent Fiber Optic Temperature Monitoring Solutions for Critical Power Assets

1. Switchgear Contact Temperature Monitoring

Technical Implementation:

  • Direct mounting on 10kV-35kV fixed contacts using ceramic insulated probes (CTI≥600)
  • 4-channel redundant measurement per circuit breaker compartment
  • 500μs response time for arc fault prediction
Parameter Specification Test Standard
Probe Diameter Φ1.5mm stainless steel sheathed IEC 62271-1
ຊ່ວງອຸນຫະພູມ -40°C to 250°C IEEE C37.20.2
Dielectric Strength 15kV AC/min (50Hz) IEC 60270

2. Oil-Immersed Transformer Winding Monitoring

Implementation Features:

  • Direct winding embedding using mineral oil-compatible FEP fibers
  • 16-point measurement per phase winding (radial distribution)
  • ±0.3°C accuracy at 100°C reference
Component Technical Solution Performance Data
Fiber Probe 3mm OD triple-jacketed assembly 25kV/mm dielectric strength
Installation Winding inter-turn insertion ≤0.2% winding deformation
Calibration In-situ oil bath calibration ±0.15°C repeatability

Global Implementation Cases

Case 1: 220kV Substation Switchgear Retrofit (Malaysia)

  • Installed 128 fluorescent sensors across 32 panels
  • Detected 5℃ abnormal temperature rise on busbar joints
  • Prevented potential $2.8M outage loss

Case 2: 500MVA Transformer Fleet Monitoring (Canada)

  • Embedded 48 fiber probes in 12 power transformers
  • Identified 8℃ hot-spot differential during peak load
  • Extended OLTC maintenance cycle by 40%

Professional Support Services

Technical Consultation

Get system design advice from certified engineers

Project Implementation

On-site installation support services

WhatsApp Inquiry

24/7 emergency support available for existing systems

ເຊັນເຊີອຸນຫະພູມ Fiber optic, ລະບົບຕິດຕາມກວດກາອັດສະລິຍະ, ຜູ້ຜະລິດໃຍແກ້ວນໍາແສງແຈກຢາຍຢູ່ໃນປະເທດຈີນ

ການວັດແທກອຸນຫະພູມໃຍແກ້ວນໍາແສງ fluorescent ອຸປະກອນວັດແທກອຸນຫະພູມໃຍແກ້ວນໍາແສງ fluorescent ລະບົບການວັດແທກອຸນຫະພູມໃຍແກ້ວນໍາແສງແຈກຢາຍ fluorescence

ການສອບຖາມ

ກ່ອນໜ້າ:

ຕໍ່ໄປ:

ຝາກຂໍ້ຄວາມໄວ້