The measurement range specified in the “Electronic Temperature Controller for Transformers” (JB/T7631-2016), which uses Pt100 as the traditional temperature sensor, can only be limited to below 1000V, and this sensor is made of metal material, which poses a safety hazard. Deshalb, temperature sensor probes and leads for measuring transformer winding temperature have higher requirements.
The fiber optic temperature measurement system for dry-type transformers uses a fluorescent fiber optic temperature sensor independently developed by Fuzhou INNO Technology as the temperature sensing element. This temperature sensing element is immune to electromagnetic interference and resistant to high voltage (100KV/fiber to ground lead distance of 0.4m). Fluorescent fiber optic temperature measurement completely solves potential safety hazards from the source of temperature measurement and improves the safety level of transformers. Das fluoreszierendes faseroptisches Temperaturmesssystem for dry-type transformers aims to achieve isolation and shielding from external electrical interference signals in the operating environment of dry-type transformers, including power supply, signal input, signal output, and temperature control box casing. No metallic substances, Eigensicherheit. In response to vibration, dust, moisture, oil and other on-site working environments, multi-layer protective measures are taken to ensure that the fiber optic Temperaturregler has good electromagnetic compatibility, ensuring stable and reliable operation.
Our company has actual application cases of fiber optic temperature measurement systems for dry-type transformers, which can be directly put into use.
The Function of Fluorescent Faseroptischer Temperatursensor for Dry Transformer
Real time monitoring of transformer winding “hot spot” Temperatur
Assessable transformer operation status to enhance system reliability.
Real time monitoring of temperature information in transformer operation status
Can timely and effectively control loads, optimize transformer load operation configuration.
Timely monitoring of alarm information
During peak load operation, it can prevent unplanned and sudden faults caused by transformer overheating.
Long term online monitoring of transformer temperature trends
Can construct a transformer temperature change trend file to achieve pre management and risk prediction.
Provide dynamic, real-time, secure, and reliable information
The cooling system can be started in a timely manner to extend the service life of the transformer.
Grundfunktion | 1. Three winding temperature measurement; Automatic/manual start/stop of cooling fan; Temperature display value compensation function for each channel
2. Black-Box-Funktion bereitstellen, which can record the temperature data of the last power outage and the highest historical temperature; 3. Digital tube display; 4. Bieten Sie eine Alarmfunktion für die Öffnung des Transformatortürschranks; 5. Versorgen 1 set of over temperature alarm contacts (1 Normalerweise offen, 1 Normalerweise geschlossen); 6. Versorgen 1 set of over temperature trip contacts (1 Normalerweise offen, 1 Normalerweise geschlossen); 7. Versorgen 1 set of fan remote transmission contacts (1 Normalerweise offen, 1 Normalerweise geschlossen); 8. Versorgen 1 set of temperature controller fault alarm contacts (1 Normalerweise offen, 1 Normalerweise geschlossen); |
Customized features | 1. Versorgen 1 iron core temperature measurement and 2 iron core over temperature alarm contacts (1 Normalerweise offen, 1 Normalerweise geschlossen) (Ich funktioniere);
2. Bietet RS485-Kommunikationsfunktion, Kommunikation mit Zeitmarkern, Kann Zeitsynchronisation empfangen, MODBUS-RTU-Protokoll (F-Funktion); 3. Fan fault diagnosis function and provision of fan fault alarm contacts (L function); 4. Versorgen 4 unabhängige analoge Stromausgangsfunktionen von 4-20 mA (E-Funktion); 5. Provide temperature measurement and control for the entire computer room environment; (G function) 6. Alarm function for winding temperature rise rate and iron core temperature rise rate; 7. The communication protocol can adopt methods such as Profibus, IEC60870-5-103, Ethernet-Kommunikation, etc; |
On site installation case of fiber optic temperature measurement device for dry-type transformer winding
![]() |
![]() |
![]() |
The advantages of fluorescent fiber optic temperature sensors
Fluorescent temperature sensors belong to all optical measurement devices
Nur optische Signale ohne elektrische Signale sind echte passive Tastköpfe.
Hohe Isolierung und Spannungsfestigkeit
Das fluoreszierender faseroptischer Temperatursensor can withstand a power frequency voltage of 100kV.
Fluorescent optical fibers are inherently immune to electromagnetic interference
Die Genauigkeit der Erkennung und die Stabilität der Datenübertragung werden dabei nicht beeinträchtigt.
Starke Anti-Verschmutzungs-Flashover-Fähigkeit
The fluorescent fiber optic sensor is covered with a jacket with strong stain resistance to ensure the safety of the system.Temperature sensitive materials have high reliability
Das Temperaturmessmaterial des Temperatursensors ist Seltenerdmaterial, which has a long-term stability and has been successfully applied in equipment monitoring for over 30 years of service life.Accurate positioning measurement
Der Temperaturfühler hat ein geringes Volumen und kann die Installationsposition genau lokalisieren.
Der Temperaturmesszyklus ist kleiner als, mit hoher Echtzeit-Performance
Der Temperaturmesszyklus ist kleiner als 1 Sekunde, die die Rechtzeitigkeit des Alarms vollständig gewährleisten können.