فائبر آپٽڪ گرمي پد سينسر, ذھني نگراني نظام, چين ۾ ورهايل فائبر آپٽڪ ٺاهيندڙ
The temperature controller of the switchgear is a temperature monitoring system that continuously monitors the operating temperature of the contacts inside the high-voltage switchgear to determine the degree of overheating at the contact joints. When overheating occurs, the instrument emits an alarm indication. Accurate and stable temperature measurement can be achieved in switchgear of various voltage levels. Please contact us by phone for specific prices.
سوئچ گيئر لاءِ فائبر آپٽڪ جي درجه حرارت جي ماپ جو نظام
The fiber optic temperature measurement system is composed of fluorescent fiber optic temperature transmitters and fluorescent fiber optic sensors, وغيره. It realizes comprehensive temperature monitoring of power equipment such as oil immersed transformers, dry-type transformers, switchgear, reactors, generator stators, high-voltage cable joints, high-voltage busbar joints, knife switches, high-voltage cable cables, وغيره. in power generation/substations. It can meet the precise point measurement inside the switchgear. The entire temperature sensing network is composed of fiber optic sensors, and the monitoring and transmission of fiber optic signals are completely free of electricity. Its excellent insulation performance does not cause lightning, and even if struck by lightning, the system can still work normally. By connecting through communication interfaces, it is possible to integrate power integrated systems, fire protection systems, وغيره. into a more powerful power intelligent integrated monitoring system.
Temperature measurement solution for switchgear temperature controller:
Monitor the temperature of the switchgear and cable joints, and achieve temperature monitoring in both areas. ساڳئي وقت ۾, the system should have expansion functions to facilitate future access of energy meter data.
There are 3 switchgear cabinets in Area A that require temperature measurement. Each switchgear cabinet monitors 6 points, totaling 18 points. ان کان علاوه, there are 21 cable intermediate joints that require temperature measurement.
There are 3 switchgear cabinets in Zone B that require temperature measurement. Each switchgear cabinet monitors 6 points, totaling 18 points. ان کان علاوه, there are 23 cable intermediate joints that require temperature measurement.
Other areas: The distribution of electricity meters is scattered, and in the future, according to the equipment renovation situation, on-site management machines can be connected nearby or new management machines can be added to achieve centralized data collection and publishing of electricity meters.